BYGPL - EASY COLOR PRIMER/SEALER, JLP

  • MSDS: BYGPL
  • Manufacturer: TRU TEST MANUFACTURING CO
  • Product Name: EASY COLOR PRIMER/SEALER, JLP
  • National Stock Number: 8030-00N062263
Product Identification

Product ID:EASY COLOR PRIMER/SEALER, JLP
MSDS Date:12/14/1993
FSC:8030
NIIN:00N062263
MSDS Number: BYGPL

Responsible Party
TRU-TEST MANUFACTURING CO
201 JANDUS RD
CARY, IL 60013
US

Emergency Phone: 800-228-5635

Info Phone: 708-639-5383

Cage: TRUTE

Contractor
TRU-TEST MANUFACTURING CO
CARY, IL 60013 US

Telephone: 708-639-5383

Cage: TRUTE

Ingredients

0.1 @ 20C.

CAS: 107-21-1

RTECS: KW2975000

Fraction By Weight: 2-4%

OSHA PEL 50 PPM (MFR)

ACGIH TLV: 50 PPM, VAPOR, C

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


SILICA, CRYSTALLINE - QUARTZ; (CRYSTALLINE SILICA)

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: 3-5%

OSHA PEL 0.1 MG/M3 (MFR)

ACGIH TLV: 0.1 MG/M3 RDUST


<150 G/L.

RTECS: 9999999VO

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHAL:VAPORS OR SPRAY MISTS MAY BE
IRRITATING TO EYES, NOSE, THROAT & MUCOUS MEMBRANES OF RESPIRATORY
TRACT. SKIN:PROLONGED OR REPEATED CONTACT MAY CAUSE IRRITATION.
EYE:DIRECT CONTACT W/PAINT WILL RE SULT IN IRRITATION.
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ:IARC
MONOGRAPHS, SUPP, VOL 7, PG 341, 1987:GRP 2A. NTP 7TH ANNUAL RPT ON
CARCINS, (SUPP DATA)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE KNOWN TO TRU-TEST
MANUFACTURING COMPANY.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. SKIN:REMOVE W/SOAP & WATER. REMOVE
CONTAMINATED CLOTHING & WASH BEFORE REUSE. EYE:FLUSH IMMEDIATELY
W/LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. SEE MD FOR
MEDICAL TREA TMENT. INGEST:GIVE 1-2 GLASSES OF WATERTO DILUTE. DO
NOT INDUCE VOMITING. CALL MD IMMEDIATELY.

Fire Fighting

Extinguishing Media:FOAM, CO*2, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROTECTIVE
EQUIP . WATER MAY BE USED TO COOL CLSD CNTNRS TO PVNT PRESS BUILD
UP & EXPLO WHEN EXPOSED TO EXTREME HEAT.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT.

Accidental Release

Spill Release Procedures:DIKE & CONTAIN SPILL W/INERT MATERIAL (SAND,
EARTH, ETC). TRANSFER LIQUID TO CONTAINERS FOR RECOVERY OR
DISPOSAL. KEEP SPILL OUT OF SEWERS & OPEN BODIES OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:"KEEP FROM FREEZING". AVOID PROLONGED
CONTACT W/SKIN. DO NOT TAKE INTERNALLY.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:WHEN BRUSHED OR ROLLED NONE REQUIRED IF GOOD
VENTILATION MAINTAINED. DURING SPRAY APPLICATION, A NIOSH/MSHA
APPROVED MECHANICAL FILTER RESPIRATOR TO REMOVE AIRBORNE PARTICLES
OF OVERSPRAY.
Ventilation:SUFFICIENT VENT SHOULD BE PROVIDED TO KEEP AIR CONTAM CONC
BELOW CURRENT APPLIC OSHA PEL OR ACGIH TLV LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:DELUGE SHOWER WHICH MEETS ANSI DESIGN
CRITERIA . EYEWASH FACILITY, PROTECTIVE CLOTHING TO AVOID EXCESSIVE
EXPOS.
Work Hygienic Practices:WASH HANDS BEFORE EATING, SMOKING OR USING
WASHROOM.
Supplemental Safety and Health
EXPLAN OF CARCIN:1994:ANTICIPATED TO BE CARCINOGEN.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SEE ING 1
Vapor Density:LTR/AIR
Spec Gravity:1.23
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:70

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:LIQUID MATERIAL & CONTAMINATED DIKING MATERIAL
SHOULD BE LANDFILLED ACCORDING TO CURRENT LOCAL, STATE & FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.